What's New

Payment of our software is possible by bank transfer
or with credit cards through PayPal.

 
October 02, 2015 

aHRV ver. 13.4.0, LT-aHRV ver. 6.1.0, SA-aHRV ver. 8.4.0,
and SA-LTaHRV ver. 5.8.0
The following feature were added:

File preparation:

  • The option to output compatible ECG signals in the TXT format which can subsequently be used by other programs.
 
September 2, 2015
   

All Nevrokard software programs and all drivers for the USB dongle are compatible with all Windows 10 versions (both 32-bit and 64-bit)
   
June 11, 2015 

aHRV ver. 13.3.0, LT-aHRV ver. 6.0.0, SA-aHRV ver. 8.3.0,
and SA-LTaHRV ver. 5.7.0
The following feature were added:

File preparation:

  • Improved compatibility with  Poly5/TMS32  data formats ver. 2.03 and 2.04 (*.S0*)  processed by PortiLab® (the TMS International® acquisition software)s was implemented.
March 12, 2015 
All programs.
The software has been re-compiled due to certificate renewal.
 
June 26, 2014 

BRS ver. 6.3.0
The following feature were added:

File preparation:

  • Improved compatibility with  Biopac® AcqKnowledge formats ver. 4.0 and 4.1 *.ACQ files was implemented.
April 19, 2014 

aHRV ver. 13.2.2 and LT-aHRV ver. 5.9.2
The following feature were added:

Analysis:

  • Improved compatibility with Bio-Impedance Technology, Inc.® CopWin® *.EMA files was implemented.
October 18, 2012
   

All Nevrokard software programs and all drivers for the USB dongle are now compatible with all Windows 8 versions (both 32-bit and 64-bit)
   
May 14, 2012 

aHRV ver. 13.1.0, LT-aHRV ver. 5.8.0, SA-aHRV ver. 8.1.0,
and SA-LTaHRV ver. 5.5.0
The following feature were added:

File preparation:

  • Improved compatibility with DSI-Ponemah® *.ASCII files was implemented.
January 16, 2012

aHRV ver. 13.0.0 and SA-aHRV ver. 8.0.0
The following features were added:

Analysis:

  • Lomb Periodogram (see the graph and compare it with the AR and FFT spectral graphs of the same ECG file), an algorithm avoiding resampling at equal intervals and producing robust power spectral density estimates in the presence of noise and ectopy, was implemented.
.

 

November 7, 2011

aHRV ver. 12.7.0 and LT-aHRV ver. 5.7.0
The following features were added:

Analysis:

  • Compatibility with GE Marquette™ holter files in the MIB format.
October 28, 2011
 

aHRV ver. 12.6.0 and LT-aHRV ver. 5.6.0

The following features were added:

File preparation:

 
  • Compatibility with Custo med (www.customed.de) binary ECG files recorded by a Custo med ECG Measuring Station (e.g. Custo cardio 100™) in the BIN format.
Analysis:
  • Compatibility with files output by the eMotion HRV monitor manufactured by Mega Electronics (www.megaemg.com) in the Suunto™ (SDF) format.
May 9, 2011 

aHRV ver. 12.5.0 and LT-aHRV ver. 5.5.0
The following features were added:

File preparation:

  • Compatibility with ECG files recorded by the Mortara  holter system in the XML format
March 3, 2011 

BPV ver. 8.9.0, SA-BPV ver. 3.6.0, BRS ver. 6.1.2 and SA-BRS ver. 4.2.0
The following features were added:

BPV and SA-BPV:

  • Compatibility with BMEYE Nexfin files in the CSV format.
  • Improved compatibility window (interface) for Finometer format- Beatscope files and MS-Excel files.
  • Use of demo file examples was made more user-friendly.

BRS and SA-BRS:

 
  • Because of links to the new Nevrokard BPV software, it is recommended that users of (SA)BPV+(SA)BRS software install the new (SA)BRS version.
January 10, 2011 

BRS ver. 6.1.0 and SA-BRS ver. 4.1.0
The following features were added:

Analysis:

 

 

  • Compatibility with BMEYE Nexfin files in the CSV format.
  • Improved compatibility window (interface) for Finometer format- Beatscope files and MS-Excel files.

January 5, 2011 
 

 

 

aHRV ver. 12.4.0, LT-aHRV ver. 5.4.0, SA-aHRV ver. 7.4.0 and SA-LTaHRV ver. 5.4.0
The following features were added:

Analysis:

 
  • Compatibility with BioPac Zephyr BioHarness files in the CSV format.
  • Compatibility with BMEYE Nexfin files in the CSV format.
  • Improved compatibility window (interface) for Finometer format- Beatscope files and MS-Excel files.

 

November 30, 2010 

aHRV ver. 12.2.0, LT-aHRV ver. 5.2.0, SA-aHRV ver. 7.2.0 and SA-LTaHRV ver. 5.2.0
The following features were added:

File preparation:

 
  • Compatibility with files recorded by the Cardionics™ E-Scope II electronic stethoscope and output by the Stethographics™ software in the WAV format.

Analysis:

  • Compatibility with GE Marquette binary holter RRI files in the QRS forma
June 17, 2010 

aHRV ver. 12.0.0 and SA-aHRV ver. 7.0.0
The following features were added:

Analysis:

 
  • A new, non-linear HRV analysis method called the CZF (Conte, Zbilut, Federici) method was added to the frequency domain methods. It can be applied in cases of non-linear and non-stationary time series and can be used to analyze the fractal variance function, the generalized fractal dimension and the relative probability density function of the data. More...

FFTSPECTRUM

April 1, 2010 

BRS ver. 6.0.0 and SA-BRS ver. 4.0.0
The following features were added:

File preparation:

  • BRS and SA-BRS programs now have their own BRS and SA-BRS File Preparation modules.

Analysis:

 
  • The Sequence Analysis of the BRS and SA-BRS programs now has, in addition to the RRI/BP calculation basis (+BP/+PI, -BP/-PI and All sequences), an alternative calculation basis of HR/BP (+BP/-HR, -BP/+HR and All sequences).
  • The complete statistics of HR is now available in tabular form.

February 4, 2010 

aHRV ver. 11.2.0 and SA-aHRV ver. 6.1.0
The following features were added:

File preparation:

  • Direct shortcut to the NEW LT-aHRV Analysis (Long-term advanced Heart Rate Variability) module.

Analysis:

 
  • Segmented Statistics: calculation of two additional parameters, RMSSD and pNN index in consecutive time segments. The pNN50, pNN27 and pNNxx radio buttons enable the operator to adjust pNNxx calculations to adult ECG, fetal ECG and ECG of any animal, large or small, respectively.

 

January 31, 2010 
 

 

LT-aHRV ver. 5.0.0 and SA-LTaHRV ver. 5.0.0

LT-HRV ver. 4.4.0 and SA-LTHRV ver. 3.3.0 will continue to be available for download in the present form until further notice. All present LT-HRV/SA-LTHRV customers may upgrade this product to LT-aHRV/SA-LTHRV ver. 5.0.0 (see Prices).

LT-aHRV ver. 5.0.0 and SA-LTaHRV ver. 5.0.0 are advanced LT-HRV/SA-LTHRV versions with the following advantages:

Analysis:

 
  • Poincare analysis -  NEW ANALYSIS. Calculation of SD1, SD2 in both absolute and normalized units, SD1/SD2 Ratio, CSI (Cardiac Sympathetic Index), CVI (Cardiac Vagal Index) in consecutive time segments.

  • A sophisticated and flexible automatic Data Editor function.
  • Segmented Statistics: calculation of two additional parameters, RMSSD and pNN index in consecutive time segments. The pNN50, pNN27 and pNNxx radio buttons enable the operator to adjust pNNxx calculations to adult ECG, fetal ECG and ECG of any animal, large or small, respectively.
  • Improved compatibility with Finometer® -Beatscope® (www.finapres.com) files was implemented:
    - Display of Event Markers is supported.
    - Display of actual time of day independent of regional formats, not just time elapsed from the start of the recording.  
    - The file may have any arbitrary extension.
    - The number of header (offset) lines is determined automatically, regardless of length.
    - The file can contain either a series of RRI's (in msec or sec), of HR data or Running Time (in sec or h:min:sec format). Running time is the time elapsed since the beginning of the recording. Any running time value minus the immediately preceding running time value equals an RRI.
  • Improvement in the Text and MS®-Excel compatibility. The program now ignores non-numeric and empty lines.
  • Improved compatibility with PowerLab® Chart text files files was implemented:
    - The number of header (offset) lines is determined automatically, regardless of length.
    - The operator may select the column in which RRI's (or HR's) are recorded
  • Compatibility with binary TXT files recorded by the Del Mar Reynolds® (now Spacelabs Medical®) Pathfinder Holter system was improved. Premature beat filtration and interpolation features are incorporated into the procedure.
  • Use of demo file examples was made more user-friendly.

File preparation:

  • The Filter Preview option enabling the operator both to check whether filtering of the signal would improve the recording and to turn the filter on/off was added.
  • Compatibility with the text data files recorded by the Physio-Logger® registration system  manufactured by med-NATIC® (Munich, Germany) (www.med-natic.de/e_phylo.htm) was implemented.
  • Compatibility with binary data files recorded by the DSI-Ponemah® (*.RAW) data acquisition and analysis system manufactured by DSI - Data Sciences International was implemented
  • Compatibility with DSI-Ponemah® *.ASCII files was implemented.
  • Compatibility with MIT format 80 files was improved.
  • Use of demo file examples was made more user-friendly.
December 17, 2009

aHRV ver. 11.1.0, BPV ver. 8.8.0, BRS ver.5.8.0, SA-BPV ver. 3.5.0 and SA-BRS ver. 3.5.0

File preparation:

  • Compatibility with Biopac AcqKnowledge formats ver. 4.0 and 4.1 was implemented.
December 14, 2009
   

All Nevrokard software programs and all drivers for the USB dongle are now compatible with all Windows 7 versions (both 32-bit and 64-bit)
   
November 11, 2009

aHRV ver. 11.0.4 and SA-aHRV ver. 6.0.1

File preparation:

  • Improved compatibility with MIT format 80 files was implemented.
September 8, 2009

BPV ver 8.7, BRS ver. 5.7, SA-BPV ver 3.4 and SA-BRS ver 3.4
The following features were added:

File preparation:

 
  • An optional setting of a time window within which the algoritm looks for the max. and min. value (SBP and DBP) has been added. By changing these parameters the user can adjust the SBP/DBP detector to the specific requirements of the recording. In this way the recording can be cleaned of any spikes and incisures arising for any reason whatsoever.

May 4, 2009

LDDA(5) ver. 8.0
The following features were added in the frequency domain analysis (FFT and AR):

  • The option to calculate spectral power also in the ULF - Ultra Low Frequency and in the VHF - Very High Frequency bands (in addition to the existing VLF, LF and HF bands). The operator can modify the number and limits of frequency bands which represent the quantitative, numeric results of spectral analysis and give a measure of microcirculation in absolute or normalized units.
  • Calculation of two additional parameters, CCVLF (Coefficient of Component Variance for LF) and CCVHF (Coefficient of Component Variance for HF).
February 23, 2009

SA-aHRV ver. 6.0
The same features were added as to aHRV ver. 11.00 on February 2, 2009

aHRV ver. 11.02 and SA-aHRV ver. 6.00
File preparation:

  • Compatibility with DSI-Ponemah® *.ASCII files was impleented.
February 2, 2009

aHRV ver. 11.0
The following features were added:

File preparation:

  • The Filter Preview option enabling the operator both to check whether filtering of the signal would improve the recording and to turn the filter on/off was added.
  • Compatibility with the binary data files recorded by the DSI-Ponemah® data acquisition and analysis system made by DSI - Data Sciences International.
  • Use of demo file examples was made more user-friendly.

 

Analysis:
  • Compatibility with binary TXT files recorded by the Del Mar Reynolds® (now Spacelabs Medical®) Pathfinder Holter system was improved. Premature beat filtration and interpolation features are incorporated into the procedure.
  • Use of demo file examples was made more user-friendly.
December 16, 2008

aHRV ver. 10.2 and SA-aHRV ver. 5.1
The following features were added:

Analysis:

  • Improved compatibility with Finometer® -Beatscope® (www.finapres.com) files was implemented:
    -
    Display of Event Markers is supported.
    - Display of actual time of day independent of regional formats, not just time elapsed from the start of the recording.
     
    - The file may have any arbitrary extension.
    - The number of header (offset) lines is determined automatically, regardless of length.
    - The file can contain either a series of RRI's (in msec or sec), of HR data or Running Time (in sec or h:min:sec format). Running time is the time elapsed since the beginning of the recording. Any running time value minus the immediately preceding running time value equals an RRI.
  • Improvement in the Text and MS®-Excel compatibility. The program now ignores non-numeric and empty lines.
  • Improved compatibility with PowerLab® Chart text files files was implemented:
    - The number of header (offset) lines is determined automatically,
    regardless of length.
    - The operator may select the column in which RRI's (or HR's) are recorded.

File preparation:

  • Compatibility with the text data files recorded by the Physio-Logger® registration system  manufactured by med-NATIC® (gmbh Munich, Germany) www.med-natic.de/e_phylo.htm.
December 5, 2008

BPV ver. 8.5 and BRS ver. 5.5
The following features were added:

Analysis:

  • Improved compatibility with Finometer® -Beatscope® (www.finapres.com) files was implemented:
    - the file may have any arbitrary extension;
    - the number of header (offset) lines is determined automatically, regardless of length;
    - the operator may select the respective columns in which RRI's (or HR), SBP, MBP and DBP are recorded;
    - if the data acquisition system used does not ouput MDP values, the user may select the CALCULATE option. If this option is selected, MDP values are calculated.
  • Improvement in the Text and MS®-Excel compatibility. The program now ignores non-numeric and empty lines.
November 24, 2008

BPV ver. 8.4, BRS ver. 5.4, SA-BPV ver. 3.3 and SA-BRS ver. 3.3

Analysis:

  • Improved compatibility with PowerLab® Chart text files files was implemented:
    - the number of header (offset) lines is determined automatically,
    regardless of length;
    - the operator may select the respective columns in which RRI's (or HR), SBP  and DBP are recorded;
    - MDP values are calculated automatically.
July 1, 2008

CVPA ver. 2.1
The following features were added:

  • Improved compatibility with Finometer® -Beatscope® (www.finapres.com) files was implemented:
    - the file may have any arbitrary extension;
    - the number of header (offset) lines is determined automatically,
    regardless of length
May 19, 2008

BPV ver. 8.3 and  BRS ver. 5.3
The following features were added:

Analysis:

  • Improved compatibility with Text format files was added, providing compatibility with Finometer® -Beatscope® text format files.

File preparation:

  • Direct access from the NK File Preparation to the new aHRV Analysis module was implemented.
April 2, 2008

Launch of SA-aHRV ver. 5.0.0, discontinuation of SA-HRV ver. 4.1.0

SA-aHRV ver. 5.0.0 was launched. This is an advanced SA-HRV version with the following advantages:

  • a sophisticated and flexible automatic Data Editor function;
  • a capability to export the selected analysis results to an Excel (CSV) spreadsheet. The results are saved in groups and automatically and sequentially appended to (a) selected CSV Results file(s);
  • continued development with software updates for the foreseeable future;
  • Improved compatibility with Excel CSV files. The program now ignores non-numeric strings and sets their value to zero;
  • While compatibility with different formats has already been independent of regional settings, it is now also independent of headers containing date/time information in various regional formats, thus enabling the software to use and display also actual time of day independent of regional formats, not just time elapsed from the start of the recording.  
February 18, 2008

aHRV ver. 10.1 and  LT-HRV ver. 4.4
The following features were added:

  • Compatibility with recordings output by the LiDCO™ plus Hemodynamic Monitor in the CSV format;
  • Compatibility with the new version 1.01 of XML files recorded by and transferred from the GPRS/Bluetooth/USB Dyna-Vision® patient monitor manufactured by RS TechMedic BV® (the Netherlands);
  • Improved compatibility with Excel CSV files. The program now ignores non-numeric strings and sets their value to zero;
  • While compatibility with different formats has already been independent of regional settings, it is now also independent of headers containing date/time information in various regional formats, thus enabling the software to use and display also actual time of day independent of regional formats, not just time elapsed from the start of the recording.
January 2, 2008

aHRV ver. 10.0.0, HRV ver. 9.4.0

HRV ver. 9.4.0 will continue to be available at the current price and in the present form until further notice. All present and future HRV customers may upgrade this product to aHRV ver. 10.0.0 (see Prices).

aHRV ver. 10.0.0 was launched. This is an advanced HRV version with the following advantages:

  • a sophisticated and flexible automatic Data Editor function;
  • a capability to export the selected analysis results to an Excel (CSV) spreadsheet. The results are saved in groups and automatically and sequentially appended to (a) selected CSV Results file(s);
  • continued development with software updates for the foreseeable future.

November 26, 2007

HRV ver. 9.4.0, LTHRV ver. 4.3.0 and OSAS ver 1.6.0

File preparation:

  • Compatibility with XML format files recorded by and transferred from the GPRS/Bluetooth/USB Dyna-Vision® patient monitor manufactured by          RS TechMedic BV® (the Netherlands) was added.
August 7, 2007

HRV ver. 9.3.0 and LTHRV ver 4.2.0

Analysis:

  • Compatibility with binary DAT files recorded by the Del Mar Reynolds® (now Spacelabs Medical®) Pathfinder Holter system was expanded. The software is now compatible with all versions of Pathfinder. The Pathfinder utilities for editing of aberrant, ectopic and missing beats are incorporated into the procedure.
July 31, 2007

LDDA(5) ver. 7.0

Nevrokard LDDA(5), a new software tool designed for Laser Doppler Data Analysis, was released.

Nevrokard™ LDDA(5) program performs Frequency Domain Analysis up to 5Hz and therefore a resampling rate of 10Hz is required.

The following features were added to the LDDA ver. 6.05:

  • Frequency domain analysis of up to 5Hz for all compatible files;
  • Direct moving from one mode of analysis to another by clicking the individual icons was added, the Back key is no longer there;
  • New Print Preview windows design;
  • Reading of source files from a CD and saving of the resulting files to a user-selectable hard disk directory; in the absence of a CD the file is written to the source file directory (as before);
  • Frequency domain analysis (AR and FFT):Calculation of two additional parameters, LF/(LF+HF) spectral power ratio and HF/(LF+HF) spectral power ratio in consecutive time segments;
  • Frequency domain analysis (FFT): Five new spectral windows were added (Blackman Exact, Blackman Harris, Chebyshev, Cosine Tappered, Kaiser).
  • Thoroughly revised, simpler and more user-friendly software design.
May 16, 2007
 

PUBLICATIONS

Please check PUBLICATIONS. If you have published any full-length research paper in which Nevrokard software was used (NO posters or abstracts only, please!) and which is not included in this list, please email us the bibliographic data and we'll include it

 
March 1, 2007

HRV ver. 9.2.0 and LTHRV ver 4.1.0

Analysis:

  • Compatibility with binary DAT files recorded by and exported from the Del Mar Reynolds® Pathfinder Holter system was added. Corrections of HRV signal for ectopic and missing beats are incorporated into the procedure.
February 5, 2007

LT-HRV ver. 4.0.0 and SA-LTHRV ver 3.0.0
The following features were added:

Analysis:

  • The key feature of the segmented HRV analysis, i.e., the Segment Settings have been substantially improved. If overlapping of segments is enabled, any percentage of overlapping between 1 and 100 percent can be selected in steps of 1 percent;

  • Compatibility with BEA files recorded by and exported from the Philips Zymed® 2010 Holter system was added;
  • The software will now work regardless of whether a decimal comma or a decimal point is used with decimal numbers, i.e., independently of the regional settings;
  • Time scale in actual time of day or in time elapsed from the start of the recording for Burdick® holter compatible files.
  • Compatibility with Suunto™ - heart rate monitors (www.suunto.com).

File preparation:

  • Improved compatibility with Text format files was added, providing compatibility with e.g. Portapres®  text format files;
  • Correction of the ECG zero line offset for Text format compatible files. Pronounced deviation of the ECG signal above or below the zero line which makes R wave detection difficult/impossible may be corrected by using the Zero Line Offset;
  • Invert function for Text Format compatible files. This is sometimes necessary because of special properties of the acquisition system or because of inverted recording electrodes.
January 21, 2007

HRV ver. 9.1.0 and SA-HRV ver 4.1.0
The following features were added:

January 18, 2007

CVPA ver. 2.0
The following features were added:

  • Compatibility with Niccomo™ - non invasive continuous cardiac output monitor manufactured by Medis Medizinische Messtechnik (www.niccomo.com).
January 07, 2007

HRV ver. 9.0.0 and SA-HRV ver 4.0.0
The following features were added:

Analysis:

 
  • Export Results: an optional software utility enabling the operator to save the selected analysis results to an Excel (CSV) spreadsheet. The results are saved in groups and automatically and sequentially appended to (a) selected CSV Results file(s). This software option will only be activated if it is paid for and the dongle is modified as required. It can be purchased either together with the Nevrokard HRV software or later on - the license can be added to the customer's existing dongle HRV license by email;
  • Compatibility with BEA files recorded by and exported from the Philips Zymed® 2010 Holter system was added;
  • The software will now work regardless of whether a decimal comma or a decimal point is used with decimal numbers, i.e., independently of the regional settings;
  • Time scale in actual time of day or in time elapsed from the start of the recording for Burdick® holter compatible files.

File preparation:

  • Improved compatibility with Text format files was added, providing compatibility with e.g. Portapres®  text format files;
  • Correction of the ECG zero line offset for Text format compatible files. Pronounced deviation of the ECG signal above or below the zero line which makes R wave detection difficult/impossible may be corrected by using the Zero Line Offset;
  • Invert function for Text Format compatible files. This is sometimes necessary because of special properties of the acquisition system or because of inverted recording electrodes.
November 20, 2006

CVPA ver. 1.0.0

Nevrokard CVPA (Cardiovascular Parameter Analysis), a new software tool designed for analysis of cardiovascular parameters recorded by Finometer® (manufactured by Finapres Medical Systems www.finapres.com) in both time and frequency domains, was released.

 

November 18, 2006

BRS ver. 5.2.2, BPV ver. 8.2.2,
SA-BRS ver. 3.2.3 and  SA-BPV ver. 3.2,3
The following features were added::

  • Three minor bugs were ironed out;
  • Four minor improvements were added, making installation of these new versions worthwhile for our customers
June 23, 2006

SA-BRS ver. 3.2.1
The following features were added:

  • Improved compatibility with the GRASS™ Gamma® text files (*.TXT and *.RRI).
May 22, 2006

HRV ver. 8.8, LT-HRV ver. 3.7, OSAS ver. 1.5,
SA-HRV ver. 3.8 and  SA-LTHRV ver. 2.7
The following features were added:

Analysis:

  • Improvement in the Text and MS-Excel compatibility. In addition to RRI and Heart Rate, ECG data may now also be displayed as Running Time. Running time (ms) is the time elapsed since the beginning of the recording. Any running time value minus the immediately preceding running time value equals an RRI.
April 3, 2006

BRS ver. 5.1, BPV ver. 8.2,
SA-BRS ver. 3.2 and  SA-BPV ver. 3.2
The following features were added:

BRS  and SA-BRS Sequential analysis:

  • Baroreflex-related RRI changes may appear only several beats after a BP change. In order to improve flexibility of our software for research under different conditions, we allowed for a user-definable lag/delay of from 0 to 14 beats (the default value is 1 beat).
  • A range of graphic improvements - drawing of points, slope and average slope in the graph can be selected.

Analysis - all programs (improvement in the Text and MS-Excel compatibility):

  • In addition to RRI and Heart Rate, ECG data may now also be displayed as Running Time. Running time (ms) is the time elapsed since the beginning of the recording. Any running time value minus the immediately preceding running time value equals an RRI.
  • If the data acquisition system used does not ouput MBP (mean blood pressure) values, the user may select the CALCULATE option. If this option is selected, MBP values are calculated according to the following formula: MBP=(SBP-DBP)/3 + DBP.

File preparation - all programs:

  • Compatibility with files acquired through the Dataquest® A.R.T. data acquisition & analysis system made by DSI - Data Sciences International®.
  • Correction of the ECG zero line offset for AcqKnowledge®, Binary format, CODAS®-WinDAQ, Dataquest® A.R.T., European Data Format (EDF/EDF+/EDF90), MS-Excel®, Poly5/TMS32, CED Cambridge Electronic Design® SON, Text format and SIGMA Medizin-Technik™ VAGUS®  compatible files. Pronounced deviation of the ECG signal above or below the zero line which makes R wave detection difficult/impossible may be corrected by using the Zero Line Offset.
  • Invert function for Binary Format,  Dataquest® A.R.T.,  CED Cambridge Electronic Design® SON, MS-Excel®,Text Format and SIGMA Medizin-Technik™ VAGUS® compatible files. This is sometimes necessary because of special properties of the acquisition system or because of inverted recording electrodes.
March 14, 2006

HRV ver. 8.7,  LT-HRV ver. 3.6, OSAS ver. 1.4
SA-HRV ver. 3.7  and  SA-LTHRV ver 2.6
The following features were added:

  • Compatibility with files acquired through the Dataquest® A.R.T. data acquisition & analysis system made by DSI - Data Sciences International®;
  • Time scale in actual time of day or in time elapsed from the start of the recording for CODAS® -WinDAQ, Dataquest® A.R.T., Poly5/TMS32 and  SON® -CED compatible files;
  • Correction of the ECG zero line offset for AcqKnowledge®, Binary-Single Channel, Cardiax®, CODAS®-WinDAQ, Dataquest® A.R.T., European Data Format (EDF/EDF+/EDF90), MIT,  Poly5/TMS32, CED Cambridge Electronic Design® SON and SIGMA Medizin-Technik™ VAGUS®  compatible files. Pronounced deviation of the ECG signal above or below the zero line which makes R wave detection difficult/impossible may be corrected by using the Zero Line Offset.
March 1, 2006

LT-HRV ver. 3.5, SA-LTHRV ver. 2.5 and  OSAS ver. 1.3
The following features were added:

  • Time scale in actual time of day or in time elapsed from the start of the recording (for EDF file format files, Mortara®, MiniMitter®, NerveExpress® and Polar® compatible files);

  • Compatibility with Poly5/TMS32 Data Format (*.S00) processed by PortiLab® (the TMS International® acquisition software);
  • Compatibility with additional MIT formats: MIT format 8, MIT format 16 and MIT format 61 (in addition to the already available MIT format 80 and MIT format 212).
February 16, 2006

HRV ver. 8.6 and  SA-HRV ver. 3.6
The following features were added:

  • Time scale in actual time of day or in time elapsed from the start of the recording (for EDF file format files, Mortara®, MiniMitter®, NerveExpress® and Polar® compatible files);

  • Compatibility with Poly5/TMS32 Data Format (*.S00) processed by PortiLab® (the TMS International® acquisition software);
  • Compatibility with additional MIT formats: MIT format 8, MIT format 16 and MIT format 61 (in addition to the already available MIT format 80 and MIT format 212).
December 14, 2005

BRS ver. 5.0 and  SA-BRS ver. 3.0
The following features were added:

  • Frequency domain analysis (FFT): Five new spectral windows were added (Blackman Exact, Blackman Harris, Chebyshev, Cosine Tappered, Kaiser);
  • Direct moving from one mode of analysis to another by clicking the individual icons was added, the Back key is no longer there;
  • New Print Preview windows design;
  • Report templates for A4 and Letter paper format; 
  • Reading of source files from a CD and saving of the resulting BRH files to a user-selectable hard disk directory; in the absence of a CD the BRH file is written to the source file directory (as before);
  • Compatibility with PowerLab® Chart text files;
  • Compatibility with European Data Format (EDF, EDF90 and EDF+);
  • Compatibility with Poly5/TMS32 Data Format (*.S00) processed by PortiLab® (the TMS International® acquisition software).
December 12, 2005

BPV ver. 8.1 and  SA-BPV ver. 3.1
The following features were added:

  • Compatibility with Poly5/TMS32 Data Format (*.S00) processed by PortiLab® (the TMS International® acquisition software).
November 29, 2005

BPV ver. 8.0 and  SA-BPV ver. 3.0
The following features were added:

  • Pulse Pressure (PP) Analysis in the time and frequency domains;
  • Statistics: calculation of two additional parameters, MSD (the mean value of successive absolute differences) and SDASD (standard deviation of standard deviations of individual segments);
  • Poincare analysis: calculation of two additional parameters, CSI (Cardiac Sympathetic Index) and CVI (Cardiac Vagal Index);
  • Frequency domain analysis (FFT and AR): calculation of four additional parameters, CCVLF (Coefficient of Component Variance for LF), CCVHF (Coefficient of Component Variance for HF), LF/(LF+HF) ratio and HF/(LF+HF) ratio;
  • Frequency domain analysis (FFT): Five new spectral windows were added (Blackman Exact, Blackman Harris, Chebyshev, Cosine Tappered, Kaiser);
  • Direct moving from one mode of analysis to another by clicking the individual icons was added, the Back key is no longer there;
  • New Print Preview windows design;
  • Report templates for A4 and Letter paper format; 
  • Reading of source files from a CD and saving of the resulting BRH files to a user-selectable hard disk directory; in the absence of a CD the BRH file is written to the source file directory (as before);
  • Compatibility with PowerLab® Chart text files;
  • Compatibility with European Data Format (EDF, EDF90 and EDF+);
  • Compatibility with PortiLab® - Poly5/TMS32 Data Format (*.S00).
November 5, 2005

HRV ver. 8.5,  LT-HRV ver. 3.4,
SA-HRV ver. 3.5  and  SA-LTHRV ver 2.4
The following features were added:

  • Compatible with Mortara® (H-Scribe) holter files (*.TXT);
  • New Print Preview windows design.
October 23, 2005

OSAS ver. 1.0.0

Nevrokard OSAS (Obstructive Sleep Apnea Screening), a new software tool designed for grading of probability of Sleep Apnea in patients, was released.

 

October 21, 2005

HRV ver. 8.4,  LT-HRV ver. 3.3,
SA-HRV ver. 3.4  and  SA-LTHRV ver 2.3
The following features were added:

  • Compatible with Cardiac Science Burdick® Vision (Premier) holter files (*.TXB);
  • Calculation of two additional parameters, LF/(LF+HF) spectral power ratio and HF/(LF+HF) spectral power ratio in consecutive time segments.
September 30, 2005

HRV ver. 8.3,  LT-HRV ver. 3.2,
SA-HRV ver. 3.3  and  SA-LTHRV ver 2.2
The following features were added:

  • Calculation of an additional parameter - MSD - the mean value of successive absolute differences  (HRV and SA-HRV software only);
  • Compatibility with PowerLab® Chart text files;
  • Improved European Data Format (EDF, EDF90 and EDF+) compatibility (independent decimal number formats (dot/comma));
  • Extended parameter settings for text files (file extension can be changed arbitrarily; blank lines will be ignored);
  • Reading of source files from a CD and saving of the resulting RRI files to a user-selectable hard disk directory; in the absence of a CD the RRI file is written to the source file directory (as before).
August 4, 2005

HRV ver. 8.2  and  SA-HRV ver. 3.2
The following features were added:

Poincare analysis - calculation of new additional parameters:

  • dRRt (maximal heart rate variability, reflecting tonic heart rate control) in absolute and normalized units;
  • dRRr (maximal response of RR interval, reflecting reflex heart rate control) in absolute and normalized units;
  • dRRt/dRRr
July 29, 2005

HRV ver. 8.1,  LT-HRV ver. 3.1,
SA-HRV ver. 3.1  and  SA-LTHRV ver 2.1
The following features were added:

  • Seven minor bugs were ironed out (none of them affecting your results, however);
  • Nineteen minor improvements were added, making installation of these new versions worthwhile for our customers
March 29, 2005

HRV ver. 8.0,  LT-HRV ver. 3.0,
SA-HRV ver. 3.0  and  SA-LTHRV ver 2.0
The following features were added:

  • Full automatic compatibility with the different Mini Mitter output formats;
  • Compatibility with Freeze-Framer files;
  • LogHRV (HRV and SA-HRV software only) and SDASD parameters were added to Statistics;
  • In Statistics (HRV and SA-HRV software only) , there are now three NN options available: NN50 for adult, NN27 for fetal and user-defined NN (for any animal species of any size and heart rate);
  • The option to select by a single click either heart rate or RRI units (HR/RR) in all time domain-related types of analysis. All time-domain displays and calculations will be done either in the RR or HR mode.
 


 

 


 

February 02, 2005

LT-HRV ver. 2.20 and SA-LTHRV ver 1.20
The following features were added:

  • An improved algorithm for R wave detection and digital filtering, reducing the time required for these procedures by about 12 times;
  • R-R intervals are now in floating point format (xxx.xx miliseconds). This improved precision is particularly important for the recordings where sampling rates are higher than 1000 Hz;
  • Compatibility with Nerve-Express® files (*.HRV);
  • Calculation of two additional parameters, CCVLF (Coefficient of Component Variance for LF) and CCVHF (Coefficient of Component Variance for HF) in consecutive time segments.

January 13, 2005

HRV ver. 7.20 and SA-HRV ver. 2.20
The following features were added:

  • An improved algorithm for R wave detection and digital filtering, reducing the time required for these procedures by about 12 times;
  • R-R intervals are now in floating point format (xxx.xx miliseconds). This improved precision is particularly important for the recordings where sampling rates are higher than 1000 Hz;
  • Direct switching from one mode of analysis to another by clicking the individual icons was added, the Back key is no longer there;
  • Poincare analysis: calculation of two additional parameters, CSI (Cardiac Sympathetic Index) and CVI (Cardiac Vagal Index);
  • Frequency domain analysis (FFT and AR): calculation of two additional parameters, CCVLF (Coefficient of Component Variance for LF) and CCVHF (Coefficient of Component Variance for HF);
  • Compatibility with Nerve-Express® files (*.HRV).
December 01, 2004

LDDA ver. 6.01
The following features were added:

- Improved channel identification;
- Frequency domain analysis of up to 5Hz for Moor® compatible files.

November 26, 2004

HRV ver. 7.10, LT-HRV ver. 2.10,
SA-HRV ver. 2.10 and SA-LTHRV ver 1.10
The following features were added:

HRV File Preparation
- The function of interim saving of long (e.g. Holter), partially edited ECG recordings was incorporated, thus making editing of 24-hr files in several separate sessions possible;
- Invert function for CED Cambridge Electronic Design® SON (*.SMR) and SIGMA Medizin-Technik™ VAGUS® (*.CVA) files;
- The option of a digital bandpass filter effectively eliminating 50/60Hz noise and baseline wandering due to patient restlessness was added.


Old Versions


New, with Filter ON

 

November 2, 2004
LDDA ver. 6.00
The following features were added:

- Compatibility with the Moor Instruments® laser Doppler blood perfusion monitor;
- Thoroughly revised, simpler and more user-friendly software design;
- The Help utility was thoroughly revised.

October 17, 2004
SA-LTHRV, ver. 1.00

Nevrokard™ SA-LTHRV is a new software package for Long-Term Heart Rate Variability Analysis in small animals. It features frequency domain analysis of up to 5Hz and a resampling rate of 10Hz. It is intended for use in animals having a considerably higher heart rate than human subjects.

The complementary File Preparation software for small animals is Nevrokard™ SA-HRVFP software.

October 10, 2004
HRV ver. 7.00, LT-HRV ver. 2.00 and SA-HRV ver 2.00
The following features were added:

Analysis
- The option to calculate spectral power also in the ULF - Ultra Low Frequency and in the VHF - Very High Frequency bands (in addition to the existing VLF, LF and HF bands) was added to the frequency domain analysis functions;
- Compatibility with the Finometer® Format - Beatscope® (*.OUT) files;
- Compatibility with the MiniAnalysis® (*.ASC) files;
- Compatibility with the multicolumn text files;
- Invert function for multichannel binary files;
- The maximum allowed recording length for HRV or LT-HRV analysis is now 5 days (previously 26 hours) and for SA-HRV analysis 27 hours (previously 7 hours).

October 7, 2004
All software products
The following features were added:

Nevrokard software is now available with dongles only. This will enable you to use the software you purchase on any computer, as long as the dongle is inserted into the appropriate USB port. Dongles are also available for owners of previous versions of the Nevrokard software. Please contact us for details: nevrokard@medistar.si.

September 18, 2004
BPV ver. 6.63, SA-BPV ver. 1.12 and BRS ver. 3.63
The following features were added:

BPV and SA-BPV Analysis
- The option to calculate spectral power also in the ULF - Ultra Low Frequency and in the VHF - Very High Frequency bands (in addition to the existing VLF, LF and HF bands) was added to the frequency domain analysis functions;
- Compatibility with the Finometer® Format - Beatscope® (*.OUT) files.

BRS Analysis  
- Compatibility with the Finometer® Format - Beatscope® (*.OUT) files.

September 6, 2004
SA-HRV ver. 1.11,  SA-BPV ver. 1.11 and SA-BRS ver. 1.11
The following features were added:

 HRV File Preparation and NK File Preparation  
- Compatibility with CED Cambridge Electronic Design® SON (*.SMR) files.

September 1, 2004
HRV ver. 6.91,  LT-HRV ver. 1.51, BPV ver. 6.62 and BPV ver. 3.62
The following features were added:

 HRV File Preparation and NK File Preparation  
- Compatibility with CED Cambridge Electronic Design® SON (*.SMR) files.

August 19, 2004
HRV ver. 6.90,  SA-HRV ver. 1.10 and LT-HRV ver. 1.50
The following features were added:

HRV File Preparation
- Compatibility with SIGMA Medizin-Technik™ VAGUS® (*.CVA) files;
- Compatibility with 12 or 16 bit data format Vitaport (*.VPD) files.

Analysis:
- Setting of Zoom limits in seconds or in hours:minutes:seconds format.

August 16, 2004
BPV ver. 6.61,  BRS ver. 3.61, SA-BPV ver. 1.10 and SA-BRS ver. 1.10
The following features were added:

NK File Preparation
- Compatibility with SIGMA Medizin-Technik™ VAGUS® (*.CVA) files;
- The option of continuous scrolling through the whole of an ECG/BP file;
- Increased flexibility of selection of the results (BRH) directory;
- Invert function for Biopac™ AcqKnowledge® and DATAQ™ WinDAQ® files.

BPV and BRS Analysis:
- Setting of Zoom limits in seconds;
- Calculation of intercept on the RRI axis added to the sequence method of BRS.

July 27, 2004
Nevrokard® SA-HRV, ver. 1.00,  Nevrokard® SA-BPV, ver. 1.00 and Nevrokard® SA-BRS, ver. 1.00

These new software packages featuring frequency domain analysis of up to 5Hz and a resampling rate of 10Hz were designed for use in small animals having a considerably higher heart rate than human subjects.

Nevrokard® SA-HRV is complementary to the Nevrokard® HRV File Preparation and Nevrokard® HRV Analysis software designed for use in human subjects.

Nevrokard® SA-BPV is complementary to the Nevrokard® NK File Preparation and Nevrokard® BPV Analysis software designed for use in human subjects.

Nevrokard® SA-BRS is complementary to the Nevrokard® NK File Preparation and Nevrokard® BRS Analysis software designed for use in human subjects.

June 16, 2004
Nevrokard LT-HRV, ver. 1.40
The following features were added:

LT-HRV Analysis:
- The allowed recording length is now 1 min to 26 hr (previously from 10 min  to 26 hr);
- Time segment minimum is now 32 sec (previously 120 sec).

 
This improvement makes segmental analysis of short recordings by the LT-HRV software possible.
May 23, 2004
Nevrokard HRV, ver. 6.80 and Nevrokard LT-HRV, ver. 1.30
The following features were added:

HRV File Preparation (HRV and LT-HRV):
- The option of continuous scrolling through the whole of an ECG file;
- Increased flexibility of selection of the RRI directory;
- Time scale in actual or elapsed time (for EDF file format).

March 23, 2004
Nevrokard HRV, ver. 6.72 and Nevrokard LT-HRV, ver. 1.22
The following features were added: 

HRV File Preparation (HRV and LT-HRV):
- Compatibility with MIT format files was added, providing compatibility with e.g. Forest Medical® Trillium Holter.
This format is also compatible with databases of electrocardiograms available in signal archives on the PhysioBank web page (MIT-BIH Database). Compatible are all records in MIT Format 80 and in MIT Format 212.

March 2, 2004
Nevrokard HRV, ver. 6.69, Nevrokard BPV, ver. 6.51, Nevrokard BRS, ver. 3.51 and Nevrokard LT-HRV, ver. 1.20
The following features were added: 

- A new method of upgrade download and installation. 
Upgrade Patches will (1) carry over your settings from the preceding version into the new one, and (2) reduce the size of the file to download by about a factor of 10.

HRV File Preparation (HRV and LT-HRV) and NK File Preparation (BPV and BRS):
- R Wave Editor has no longer any limitations whatsoever as far as the length of the file and the number of edited R waves is concerned.

LT-HRV Analysis:
- Improvements of print procedures. 

February 2, 2004
Nevrokard BPV, ver. 6.50 and Nevrokard BRS, ver. 3.50
The following features were added: 

- A new method of software registration and copy protection of Nevrokard BPV and BRS software.

NK File Preparation:
- Compatibility with text format files with modifiable extensions was added, providing compatibility with e.g. Axon® format files (*.ABT).

BPV and BRS Analysis:
- Compatibility with multichannel text format files regardless of their extensions was added. This provides compatibility e.g. with the old MS-DOS Finapres® recordings.

January 15, 2004
Nevrokard HRV, ver. 6.67 and Nevrokard LT-HRV, ver. 1.02
The following features were added:

HRV File Preparation
- invert function for Biopac™ AcqKnowledge® and DATAQ™ WinDAQ® files;
- EDF files: start date and start time can be written from the EDF file into the RRI file; the time format in the output file (elapsed time, actual time) can be selected.

HRV Analysis and LT-HRV Analysis
- compatibility with Del Mar Reynolds™ Holter files;
- compatibility with Mini Mitter™ Mini-Logger 2000 Series files.

October 27, 2003
Nevrokard® LT-HRV, ver. 1.01

This completely new software package featuring advanced graphics was designed to perform analysis of long-term segmented ECG (usually Holter-recorded) recordings (from 10 min. up to 26 hrs) in the time and frequency domains. It is complementary to the Nevrokard® HRV Analysis software.

September 28, 2003
Nevrokard HRV, ver. 6.65
The following features were added:

HRV File Preparation
- compatibility with Cardiax™ CSV ECG recordings. 

HRV Analysis
- compatibility with Zymed™ (Philips™) Holter RRI files;
- five new spectral windows were added (Blackman Exact, Blackman Harris, Chebyshev, Cosine Tappered, Kaiser);
- the Poincare Analysis algorithm was improved to make it 9 times faster.

August 28, 2003
Nevrokard HRV, ver. 6.63
The following features were added:

- the re-sampling procedure was modified, so that the time required for preparation of long RRI files was shortened by a factor of 6.

August 6, 2003
Nevrokard HRV, ver. 6.62, Nevrokard BPV, ver. 6.43 and Nevrokard BRS, ver. 3.43
The following features were added:

Nevrokard HRV
- the software now uses the Polar® event markers;
- compatibility with the XLTEC® text files (*.TXT);
- the software now uses the event markers also in the File Preparation module (for Biopac™ AcqKnowledge® and DATAQ™ WinDAQ® files).

Nevrokard BPV and Nevrokard BRS
- compatibility with the GRASS™ Gamma® text files (*.TXT and *.RRI);
- the software now uses the event markers also in the File Preparation module (for Biopac™ AcqKnowlwdge® and DATAQ™ WinDAQ® files)

July 22, 2003
Nevrokard HRV, ver. 6.60, Nevrokard BPV, ver. 6.40 and Nevrokard BRS, ver. 3.40
The following features were added:

HRV File Preparation (HRV)
- The CODAS data format is now supported, the software is compatible with WinDAQ files (*.WDQ). Display of Event Markers is supported.
- The option to set an Offset value was added for EDF (European Data Format) files.

NKFP File Preparation (BPV and BRS)
- The CODAS data format is now supported, the software is compatible with WinDAQ files (*.WDQ). Display of Event Markers is supported.
- The design of user dialog was improved for ACQ (AcqKnowledge® data format) files.

July 16, 2003
Nevrokard HRV, ver. 6.50, Nevrokard BPV, ver. 6.30 and Nevrokard BRS, ver. 3.30
The following features were added:

- Improved BIOPAC AcqKnowledge® (*.ACQ) compatibility: the software now uses the ACQ event markers.

July 6, 2003
Nevrokard HRV, ver. 6.43
The following features were added:

HRV File Preparation:
- Improved compatibility with European Data Format (*.EDF and *.REC) files was added:
(a) compatibility with EDF, EDF90 and EDF+ formats,
(b) both single channel and multiple channel recordings are now supported,
(c) two formats (Little Endian, Big Endian) are now available (Intel or Motorola processor),
(d) Invert function was added,
(e) option to rescale the signal was added.

April 9, 2003
Nevrokard BPV, ver. 6.20, and Nevrokard BRS, ver. 3.20
The following features were added:

NK File Preparation:
- Compatibility with BIOPAC AcqKnowledge® multichannel binary files (*.ACQ) was added.

April 6, 2003
Nevrokard HRV, ver. 6.40
The following features were added:

HRV File Preparation:
- Compatibility with BIOPAC AcqKnowledge® multichannel binary files (*.ACQ) was added.

March 16, 2003
Nevrokard HRV, ver. 6.31
The following features were added:

HRV Analysis:
- The software was made suitable for HRV analysis of fetal ECG.

March 10, 2003
Nevrokard HRV, ver. 6.30, Nevrokard BPV, ver. 6.10 and Nevrokard BRS, ver 3.10
The following features were added:

HRV File Preparation and NK File Preparation:
- Compatibility with Data Translation® multichannel binary files (*.RAW)
was added.

February 17, 2003
Nevrokard BPV, ver. 6.00 and Nevrokard BRS, ver 3.00
The following features were added:

File Preparation:
- Thoroughly revised, simpler and even more user-friendly software design.
- Two new compatible formats were added:
     (a) The program is now compatible with Portapres™-generated text files.
     (b) Two separate binary files containing the ECG and BP signals, respectively, can now be used with the software.
- Parameter settings for all compatible formats were extended.
- The R Wave Detection algorithm was improved.
- Direct access from the File Preparation module to the Nevrokard BPV Analysis, BRS Analysis and HRV Analysis modules was implemented.
- The Help utility was thoroughly revised.

BPV and BRS Analysis:
- Chart Editor enabling graph settings (axis, axis text, font selection, font size selection, graph position etc., in short everything required for print-out of the graph in a form required for publication or for a poster), was added to all modes of analysis.
- Compatibility with Microsoft Excel multicolumn files (*.CSV) was added.

Nevrokard HRV, ver. 6.22
The following features were added:

File Preparation:
- The software is now also compatible with files created by the Rozinn Holter system.

February 9, 2003
Nevrokard HRV, v. 6.21
The following features were added:

HRV File Preparation:
- A new compatible format was added. Program is now compatible with text files created by the Adinstruments Chart™ software.

February 4, 2003
Nevrokard HRV, v. 6.2
The following features were added:

HRV Analysis:
1. Compatibility with Microsoft Excel multicolumn files (*.CSV).
2. Extended parameter settings for text files.

January 27, 2003
Nevrokard HRV, v. 6.1
The following features were added:

HRV File Preparation:
- New, simple and user-friendly software design, enabling the operator to miss all technical aspects of the operation which are not required in her/his specific case.
- Two new compatible formats (Multi-Column Text Format, Embla Format) were added.
- The R Wave Detection algorithm was improved.
- Parameter settings for compatible formats were extended.
- Direct access from the HRV File Preparation to the HRV Analysis modules was implemented.
- The Help utility was thoroughly revised.

HRV Analysis:
- The program can now also be launched automatically by double-clicking an RRI file icon.

November 18, 2002
Nevrokard HRV, v. 6.0
The following features were added:

HRV Analysis:
- Data Editor - capability to edit RR interval files, even in cases where a recording, e.g. in the binary form, is not present (e.g. Polar(R) files or text RRI files).
- Compatibility with the tab delimited single column text format RRI files.

October 14, 2002
Nevrokard HRV v. 5.6, BPV v. 5.3, BRS v. 2.2 and LDDA v. 5.2:

From now on all Nevrokard EVAL (evaluation) programs downloadable from our website will no longer 'die' after the expiration of the evaluation period, but will be converted into DEMO programs which will not be time-limited, but will have restricted capabilities (no PRINT and SAVE functions, a few numerical results will be unavailable). Even if your EVAL version stopped working at any time in the past, you can download the new EVAL version now and it will work as DEMO.
Nothing will change for registered users.

September 30, 2002
Nevrokard HRV, v. 5.5:
The following features were added:

File Preparation: 
-
 
compatibility with single column text format, with or without a header. This format provides for compatibility with any data acquisition system capable of exporting the recorded file in the single column text format (e.g. the BIOPAC® system);
- an additional option to select a sampling rate for the input binary file. The default rate is 500 Hz, but any sampling rate between 250 Hz and 10 kHz may be selected.

August 1, 2002
Nevrokard BPV, v. 5.2 and Nevrokard BRS, v. 2.1:
The following features were added:

HPMA File Preparation:
-
 
compatibility with text format and CSV format recordings acquired by any acquisition system; Nevrokard BRS is therefore now compatible with files recordings by the PowerLab® data acquisition system manufactured by ADInstruments®;
- a choice of sampling rates for binary, TXT and CSV files (default: 500 Hz).

May 29, 2002
Nevrokard HRV, v. 5.4:
The following features were added:

File Preparation:
- compatibility with the Vitaport format,
- compatibility with the European Data Format,
- the option to choose the time axis either in seconds or in hours:minutes:seconds (for very long files),
- a choice of sampling rates (500 Hz or 512 Hz).

HRV Analysis:
- compatibility with single-column TXT files,
- the option to choose the time axis either in seconds or in hours:minutes:seconds,
- Chart Editor enabling graph settings (axis, axis text, font selection, font size selection, graph position etc., in short everything required for print-out of the graph in a form required for publication or for a poster), added to all modes of analysis.